Delta RMC101 Manual de usuario Pagina 821

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 951
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 820
Appendix C: Parameter Field Reference
C-51
C.4.3 Configuration Bits - Quadrature/Stepper Specific
For quadrature axes, these bits are used to select the active states of four inputs and to define
the use of the Home Input status bit in the Status word.
Fault Input Active State - Bit 15
This bit determines the active state of the Fault Input. The active state of this input indicates that
a fault has occurred. The Encoder Error status bit is set when the Fault input is active.
Vista de pagina 820
1 2 ... 816 817 818 819 820 821 822 823 824 825 826 ... 950 951

Comentarios a estos manuales

Sin comentarios