Position/Pressure Control 4.12
Controller Features 4-45
1024 into the counts field.
o …increasing counts is selected in the Increasing counts equal… field.
In the Extend/Retract Limits field, click Set limits to the following values:. Set the desired
extend and retract limits to 0.100 and 52 inches. This system can extend 52.700 inches, but it is
undesirable to ever reach either end.
Click Apply and Done.
Issue a Set Parameters (P) command to Axis 0.
The main RMCWin window looks now like this:
This example is continued in the next topic.
4.12.4 Position-Pressure Example (Part 2)
This is part 2 of the complete step-by-step example of setting up and tuning a position/pressure
axis.
Part 2: Tuning position.
Now the system is set up and ready to tune for position. The procedure in Tuning a Position Axis is