Delta LTL2000S Especificaciones

Busca en linea o descarga Especificaciones para Telescopios Delta LTL2000S. Delta LTL2000S Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 55
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
DELTA - Hjortekærsvej 99 - DK -Kgs. 2800 Lyngby - Denmark - Tlf (+45) 45 88 83 33 - Fax (+45) 45 87 08 10
LTL2000 RETROMETER
Manual
On site quality control of road markings & road surfaces in accordance with CEN specifications
Vista de pagina 0
1 2 3 4 5 6 ... 54 55

Indice de contenidos

Pagina 1 - LTL2000 RETROMETER

DELTA - Hjortekærsvej 99 - DK -Kgs. 2800 Lyngby - Denmark - Tlf (+45) 45 88 83 33 - Fax (+45) 45 87 08 10LTL2000 RETROMETERManual

Pagina 2

DELTA LTL2000 Retrometer 4Edit the value until it corresponds with the Normal value and then press <ENTER>. The Calibrationis now completed and

Pagina 3

DELTA LTL2000 Retrometer 5

Pagina 4

DELTA LTL2000 Retrometer 6CommunicationUse a simple terminal or PC with communication software to control the LTL2000. (Windows HyperTerminal will do

Pagina 5

DELTA LTL2000 Retrometer 7SECTION 2GENERAL INFORMATIONRl MeasurementLTL2000 Retrometer measures the Rl (coefficient of retro reflected luminance) par

Pagina 6

DELTA LTL2000 Retrometer 8The LTL2000 is controlled by a microprocessor. The microprocessor executes the measurementautomatically by the push of a bu

Pagina 7 - LTL2000 Introduction

DELTA LTL2000 Retrometer 9The LTL2000 Retrometer is a rugged instrument, but it is an optical instrument and must be handled assuch.The LTL2000 is fa

Pagina 8 - LTL2000 Retrometer features:

DELTA LTL2000 Retrometer 10SECTION 3KEYBOARD, DISPLAY AND FUNCTIONSKeyboard LayoutRLTESTCALIB.ZEROENTERCANCELMENU OFF2'ndPRINTFEEDéêONKeyboard f

Pagina 9 - Calibration:

DELTA LTL2000 Retrometer 11Warning for full Test log (can be disabled)Warning for pour measurement conditionsCALIB Activates calibration measurement.

Pagina 10 - Test, warning and errors

DELTA LTL2000 Retrometer 12Result PrintoutRl PrintoutThe Rl result printout showing the measured Rl, the date and time for the measurement, the instr

Pagina 11 - DELTA LTL2000 Retrometer 5

DELTA LTL2000 Retrometer 13Test PrintoutThe Test Printout showing the measured Rl, the date and time for the test, the related status code anda T# nu

Pagina 13 - Rl Measurement

DELTA LTL2000 Retrometer 14Zero PrintoutThe printout after a Zero measurement showing the measured Zero Signal in % of the nominal signal, ifthe zero

Pagina 14 - Optical principle

DELTA LTL2000 Retrometer 15Functions and Menu systemRl Calibration(Activate with the <Calib.> key)LCD Display Explanation.Rl Normal Cal.Enter T

Pagina 15 - DELTA LTL2000 Retrometer 9

DELTA LTL2000 Retrometer 16Test Log(Select with the <Menu> key)LCD Display Explanation.Free T_LOG:95.6%Enter to ClearThe display shows the free

Pagina 16 - Keyboard functions

DELTA LTL2000 Retrometer 17é to Change Press é to disable <ENTER> to accept.Clear Top Log(Activate with the <é> key after a Rl measureme

Pagina 17 - DELTA LTL2000 Retrometer 11

DELTA LTL2000 Retrometer 18Date and Time(Activate with the <Menu> key)LCD Display Explanation.Date and timeEnter to EditThe built-in real time

Pagina 18 - Result Printout

DELTA LTL2000 Retrometer 19Status(Select with the <Menu> key)LCD Display Explanation.Status DisplayUse éê to ViewThe results and status made wi

Pagina 19 - Test Printout

DELTA LTL2000 Retrometer 20The amount of free log entries in %.Test Log Full orFree T_Log: 87.5%A warning is given if the Rl Test Log has run fu

Pagina 20 - Calibration Printout

DELTA LTL2000 Retrometer 21LTL2000 Command setThe LTL2000 is equipped with a serial communication port primarily for log data acquisitio

Pagina 21 - Functions and Menu system

DELTA LTL2000 Retrometer 22LTL2000 command setCommand Parameter Response MeaningVBat Lamp Off: 12.21 VVBat Lamp On: 11.30 VBattery volta

Pagina 22 - Print Rl Log

DELTA LTL2000 Retrometer 23LTL2000 command setCommand Parameter Response MeaningLS none Rl DataLog: 6 data points.99.56% freeRl TestLo

Pagina 23 - Measurement ID

DELTA LTL2000 RetrometeriDISCLAIMERThe information contained in this document is subject to changewithout notice.DELTA LIGHT & OPTICS MAKES NO WA

Pagina 24 - Default setting

DELTA LTL2000 Retrometer 24LTL2000 command setCommand Parameter Response MeaningLT none LTL2000 Test Log Dump: 1997 Mar 27 10:01:033 ent

Pagina 25 - DELTA LTL2000 Retrometer 19

DELTA LTL2000 Retrometer 25LTL2000 command setCommand Parameter Response MeaningRL none *** Rl Measurement ***1997 Mar 27 10:00:59Rl: 14

Pagina 26 - DELTA LTL2000 Retrometer 20

DELTA LTL2000 Retrometer 26LTL2000 command setCommand Parameter Response MeaningWarning: Low VBat Warning for low battery voltageTI none

Pagina 27 - LTL2000 command set

DELTA LTL2000 Retrometer 27LTL2000 command setCommand Parameter Response MeaningMC Average Measuring CountOT n Auto Off TimerQuery/Set t

Pagina 28

DELTA LTL2000 Retrometer 28SECTION 4MAINTENANCEGeneral careThe Retrometer is constructed for outdoor use in ordinary go

Pagina 29

DELTA LTL2000 Retrometer 29FusesFuses, two pieces, are placed at the rear of the instrument. The charging fuse protects

Pagina 30

DELTA LTL2000 Retrometer 30Light trapZero signal is simulated by a light trap made of two glossy and black plastic shee

Pagina 31

DELTA LTL2000 Retrometer 31calculates the calibration factor. This process is fully automatic and if the calibration r

Pagina 32

DELTA LTL2000 Retrometer 32PrinterThe printer is a high speed high quality Mini Thermal Printer. It uses 57.5 mm therma

Pagina 33

DELTA LTL2000 Retrometer 33

Pagina 34 - Protection window

DELTA LTL2000 RetrometeriiINDEXSECTION 1...

Pagina 35 - Calibration unit

DELTA LTL2000 Retrometer 34APPENDIX ACOMMUNICATION FACILITIESRS-232C specificationThe LTL2000 is equipped with a commun

Pagina 36 - Calibration

DELTA LTL2000 Retrometer 35Connections in the 9 pin D-Sub connector.pin # Function Signal Direction3 Receive

Pagina 37

DELTA LTL2000 Retrometer 36Connection example #2. PC with 9 pin D-Sub communication port.Cable connections:PC Port DTE

Pagina 38

DELTA LTL2000 Retrometer 37

Pagina 39

DELTA LTL2000 Retrometer 38Command formatAll LTL2000 commands are built using the following template.Command (one ore m

Pagina 40 - RS-232C specification

DELTA LTL2000 Retrometer 39APPENDIX BSpecial Status Printouts.The LTL2000 can print a special status at power up showin

Pagina 41

DELTA LTL2000 Retrometer 40Initial StatusAfter executing a ZERO function the status will looklike this.It shows that no

Pagina 42 - Data protocol

DELTA LTL2000 Retrometer 41Status after first ZeroAfter executing a ZERO function the status will looklike this.It show

Pagina 43

DELTA LTL2000 Retrometer 42Status after CalibrationAfter executing a Calibration function the status willlook like this

Pagina 44 - Command format

DELTA LTL2000 Retrometer 43Status after Rl measurementAfter executing a Normal Rl Measurement the statuswill look like

Pagina 45 - Special Status Printouts

DELTA LTL2000 RetrometeriiiSpecial Status Printouts...

Pagina 46 - Initial Status

DELTA LTL2000 Retrometer 44Status after a Test measurementAfter executing a Test Measurement the status willlook like t

Pagina 47 - Status after first Zero

DELTA LTL2000 Retrometer 45APPENDIX CSPECIFICATIONGeneral CharacteristicsIllumination angle ...

Pagina 48 - Status after Calibration

DELTA LTL2000 Retrometer 46Environmental CharacteristicsTemperature:Operating...

Pagina 49 - Status after Rl measurement

DELTA LTL2000 Retrometer 47Dimensional drawings

Pagina 50

DELTA LTL2000 Retrometer 48Instrument Layout.

Pagina 51 - Electrical Characteristics

DELTA LTL2000 Retrometer 49Calibration Unit Placement Graphics.The graphics show t

Pagina 53 - Dimensional drawings

DELTA LTL2000 Retrometer 1SECTION 1OPERATING INFORMATIONLTL2000 IntroductionThe LTL2000 Retrometer is a portable field instrument, intended for measu

Pagina 54 - Instrument Layout

DELTA LTL2000 Retrometer 2The LTL2000 is powered by a rechargeable lead acid battery, giving several hours of measurementcapacity. A mains powered ba

Pagina 55

DELTA LTL2000 Retrometer 3Getting started:Turn the LTL2000 on by pressing <ON>Hold <ON> pressed until LCD shows:Calibrate instrument if n

Comentarios a estos manuales

Sin comentarios